4X50mm2 95mm 4 core XLPE power cable Underground XLPE power cable Copper power cable

4x50mm2 95mm 4 Core Xlpe Power Cable Underground Xlpe Power Cable Copper Power CableIEC60502, BS6346, VDE, AS/NZS, UL, etc The Rated Voltage(kv):1st  class 0.6/1 1.8/3 3.6/6 6/10 8.7/15 12/20 18/30 21/35 2nd class 1/1 3/3 6/6 8.7/10 12/15 18/20 - 26/35Application:XLPE insulated power cable has a num

Featured Products

4x50mm2 95mm 4 Core Xlpe Power Cable Underground Xlpe Power Cable Copper Power Cable
IEC60502, BS6346, VDE, AS/NZS, UL, etc 

The Rated Voltage(kv):

1st  class 0.6/1 1.8/3 3.6/6 6/10 8.7/15 12/20 18/30 21/35 
2nd class 1/1 3/3 6/6 8.7/10 12/15 18/20 - 26/35

Application:

XLPE insulated power cable has a number of advantages compared with paper insulated and PVC insulated cables. XLPE cable has high electric property, mechanical property, heat aging performance, environmental stress crack resistance, chemical corrosion resistance, and it also has simple structure, convenient operation and it is not restricted by laying in large difference of level. It can be applied in high temperature of 90 degree for a long time.
PVC insulated power cable is suitable for laying fixed in power transmission and distribution lines with A.C. 50HZ and rated voltage of 0.6/1kV.

TYPE

NAME

Main Application

CU core

AL core

YJV/YJY

YJLV/YJLY

XLPE insulated,PVC/PE sheathed power cable

For laying indoor ,tunnel,canal and underground.
Unable to bear external mechanical forces,
but bear the traction force during laid

YJV22/YJV23

YJLV22/YJLV23

XLPE insulated,steel tape armored,
PVC/PE sheathed power cable

For laying indoor ,tunnel,canal and underground.
Able to bear external mechanical forces,
but unable to bear large pulling force

YJV32/YJV33

YJLV32/YJLV33

XLPE insulated,thin steel wire armored,
PVC/PE sheathed power cable

For laying in shaft,water underground will large difference of level.
Able to bear external mechanical forces and moderate pulling force

YJV42/YJV43

YJLV42/YJLV43

XLPE insulated,thick steel wire armored,
PVC/PE sheathed power cable

For laying in water and seabed.
Able to bear positive pressure and pulling force

Number of cores:

1core 2core 3core 3+1core 4core 4+1core 4+2core 5core and so on.

Nominal Section 
Area(mm2) :1.5 2.5 4 6 10 16 25 35 50 70 95 120 150 185 240 300 400 500 630 800

Features:

1). XLPE insulated power cable not only has excellent electric, mechanical properties, but also has powerful resistance against chemical erosion, heat-aging and environmental stress.
2) .Its structures are simple. The long term operating temperature is +90 degrees. It is convenient to use and can be laid with no restriction of different level.
3). Our XLPE cables can be produced according to our specification which is equivalent to IEC 502-1983, and its some indexes are superior to 502-1983.
4). We can design and manufacture special XLPE cable according to the other standards required by the customers.
5).Application: for laying indoor, tunnel, canal and underground. 

Specification
4X50mm2 95mm 4 Core XLPE Power Cable Underground XLPE Power Cable Copper Power Cable

Nominal
Cross Section
Diameter of
Conductor
(Approx.)
Nominal
Insulation
thickness
Nominal Inner
Covering
thickness
Nominal
Alum Wire
dia.
Nominal
Sheath
thickness
Overall
Diameter
(Approx.)
mm²mmmmmmmmmmmm
1x42.30.710.81.810.9
1x62.80.710.81.811.4
1x103.60.710.81.812.2
1x164.50.710.81.813.1
1x255.60.910.81.814.6
1x356.70.911.251.816.6
1x508111.251.818.1
1x709.41.111.251.819.7
1x95111.111.61.822
1x12012.41.211.61.823.6
1x15013.81.411.61.825.4
1x18515.31.611.61.827.4
1x24017.51.711.61.929.9
1x30019.51.812233.1
1x40022.621.222.237.3
1x50025.22.21.222.340.5
 
Nominal
Cross Section
Diameter of
Conductor
(Approx.)
Nominal
Insulation
thickness
Nominal Inner
Covering
thickness
Nominal
Steel Wire
dia.
Nominal
Sheath
thickness
Overall
Diameter
(Approx.)
mm²mmmmmmmmmmmm
2x1.51.40.710.81.812.8
2x2.51.80.710.81.813.6
2x42.30.710.81.814.6
2x62.80.711.251.816.5
2x103.60.711.251.818.1
2x164.50.711.251.819.9
2x255.60.911.61.823.6
2x356.70.911.61.825.8
2x508111.61.929
2x709.41.1122 .33.2
2x95111.11.22.137.1
2x12012.41.21.222.340.5
2x15013.81.41.22.52.445.4
2x18515.31.61.42.520.649.9
2x24017.51.71.42.520.755.1
2x30019.51.81.62.520.960.2
2x40022.621.62.530.167.7
 
Nominal
Cross Section
Diameter of
Conductor
(Approx.)
Nominal
Insulation
thickness
Nominal Inner
Covering
thickness
Nominal
Steel Wire
dia.
Nominal
Sheath
thickness
Overall
Diameter
(Approx.)
mm²mmmmmmmmmmmm
3x1.51.40.710.81.813.2
3x2.51.80.710.81.814.1
3x42.30.710.81.815.2
3x62.80.711.251.817.1
3x103.60.711.251.818.9
3x164.50.711.251.820.8
3x255.60.911.61.824.7
3x356.70.911.61.827.2
3x508111.61.930.6
3x709.41.1122.135.2
3x95111.11.222.239.3
3x12012.41.21.222.343
3x15013.81.41.42.52.548.6
3x18515.31.61.42.52.753
3x24017.51.71.42.52.858.5
3x30019.51.81.62.5364
3x40022.621.63.153.373.5
 
Nominal
Cross Section
Diameter of
Conductor
(Approx.)
Nominal
Insulation
thickness
Nominal Inner
Covering
thickness
Nominal
Steel Wire
dia.
Nominal
Sheath
thickness
Overall
Diameter
(Approx.)
mm²mmmmmmmmmmmmmmmm
3x 16/104.53.60.70.711.61.822.7
3x 25/165.64.50.90.711.61.826.5
3x 35/166.74.50.90.711.61.929
3x 50/2585.610.911.62.133
3x 70/359.46.71.10.91.222.238
3x 95/501181.111.222.342.4
3x120/7012.49.41.21.11.222.548
3x150/7013.89.41.41.11.42.52.752
3x185/9515.3111.61.11.42.52.857.2
3x240/12017.512.41.71.21.62.53.164
3x300/15019.513.81.81.41.62.53.269.8
 
Nominal
Cross Section
Diameter of
Conductor
(Approx.)
Nominal
Insulation
thickness
Nominal Inner
Covering
thickness
Nominal
Steel Wire
dia.
Nominal
Sheath
thickness
Overall
Diameter
(Approx.)
mm²mmmmmmmmmmmm
4x1.51.40.710.81.814
4x2.51.80.710.81.814.9
4x42.30.711.251.817
4x62.80.711.251.818.2
4x103.60.711.251.820.2
4x164.50.711.61.823
4x255.60.911.61.826.7
4x356.70.911.61.929.5
4x5081122.134.2
4x709.41.11.222.238.8
4x95111.11.222.342.9
4x12012.41.21.42.52.548.6
4x15013.81.41.42.52.753.2
4x18515.31.61.42.52.858.1
4x24017.51.71.62.53.164.8
4x30019.51.81.62.53.270.4
4x40022.621.83.153.681.3

1). Rated Voltage, No. of Core and Range of Sectional Area

Rated voltage (kv)
Sectional area (mm2)
No. of core
1st class0.6/11.8/33.6/66/108.7/1512/2018/3021/35
2nd class1/13/36/68.7/1012/1518/20-26/35
1 Core 1.5-80025-80025-120025-120035-120050-120050-120050-1200
2 Core 1.5-18525-185      
3 Core 1.5-40025-40025-40025-40035-40050-40050-40050-400
4 Core 2.5-40025-400      
5 Core 2.5-40025-400      

 2).  DC resistance: conductor resistance of finished cable at 20ºC per kilometer is not more than the following values.
Nominal section area (mm2)1.52.54610162535507095120150185240300400500630800
Copper core12.17.414.613.081.831.150.7270.5240.3870.2680.1930.1530.1240.0990.07540.06010.0470.03660.02830.0221
Aluminum core18.112.17.414.613.081.911.20.8680.6410.4430.320.2530.2060.1640.1250.10.7780.06050.04690.0367

 3). Voltage Test and Partial Discharge Test
Rate voltage Uo (kv)
Item
0.6/11.8/33.6/66/6 6/108.7/10 8.7/1512/2018/20 18/3021/3526/35
VoltageTest voltage3.56.512.52130.5426373.591
Test time555555555
Partial discharge testTest voltage--6.210.415.120.831.136.345
Discharge capacity--10101010101010

Packaging
Packing Details  : Packing in wooden drum, iron-wooden drum or as customer's requirement.
Delivery Details : 15-25 days after place an order.
4X50mm2 95mm 4 Core XLPE Power Cable Underground XLPE Power Cable Copper Power Cable

About Us
Henan Kingyear Aluminum Industrial Co., Ltd was founded in 2006, located in Gongyi industry area of Henan Province. Our company consists of 3 main subsidiaries, business specialized in develop, manufacture and distribution of Aluminum products. Our factories zone occupies more than 1200,000 square meters and the employees' number has exceeded 200.
We, Kingyear, dedicate ourselves to be a manufacturer of providing comprehensive solutions and customized services to help our customer to solve their problems and improve their profit.
We have a professional sales team with each of them has engaged in this job for 10 years, so that we can provide the comprehensive and professional technology for you.
With the perfect quality and after sales service, till now we have exported to more than 80 countries, welcome to visit us and establish win-win business relationship!

4X50mm2 95mm 4 Core XLPE Power Cable Underground XLPE Power Cable Copper Power Cable

Our Service:
1.10 years production experience and 10 years export experience .
2.Products certification :ISO,SGS,CE,BV
3.OEM service available based on official & legal authorization.
4.Strict quality control system.
5.Rapid delivery and feedback,Faster lead time than our competitors.
6.Excellent quality with reasonable price.
7.Strong technical support (technical data, drawing, etc.)
8.Professional teamwork service for you actively.
9.Stock available, Free sample is available.

FAQ
Q:I didn't find the product which I need in this page?
A:If you didn't find the species of the produxts you need, please contact us directly, we will reply you quickly.
Q:What's your minimum order quantity?
A:It is not so sure, you can confirm it with us. Normally, it will be 5 tons.
Q:What's your delivery time?
A:It depends on whether we just has the stock for your type.Normally,it takes about 7-15days to achieve production.
Q:How can I get a sample from your company? Is the sample free?
A:If you need the sample to check the quality, please contact us, we will send you the free sample, but the freight charge should be paid.
Q:What if the product which we need have some differences on specifications from yours?
A: Any difference, we can design and produce according to your requests, which include size, color, material, processing requirement etc.


Just leave your message if you are interested in our products,We will contact you very soon!
 

Contact us

Please feel free to give your inquiry in the form below We will reply you in 24 hours